Analisis Perbedaan Kekuatan Struktur Kolom Akibat Tsunami pada Gedung Laboratoriom Dinas PUPR Kota Banda Aceh

Authors

  • Mhd. Arief Diana Universitas Samudra
  • Michel Kasaf Universitas Samudra
  • Taufik Taufik Universitas Gunung Leuser Aceh
  • Khairul Anwar Universitas Gunung Leuser Aceh
  • Deni Trianda Pitri Universitas Gunung Leuser Aceh

DOI:

https://doi.org/10.55123/insologi.v4i3.5510

Keywords:

Tsunami, Hammer Test, Concrete Strength, Building Feasibility, Post-Disaster Assessment

Abstract

The earthquake and subsequent tsunami that struck Banda Aceh at the end of 2004 caused extensive damage to various infrastructures, including the Laboratory Building of the Public Works Department of Banda Aceh City. This study aims to evaluate the variation in concrete strength between columns that were submerged during the tsunami and those that remained unaffected. A non-destructive testing (NDT) method was employed, using a Concrete Hammer Test device to assess the condition of the concrete. The testing was conducted on first-floor columns, with each column section tested 12 times at intervals of 3 cm between points. The results indicate a significant reduction in compressive strength, with the most severe decline observed in column K.6.4, where a 57% strength loss was recorded due to porous concrete conditions. The smallest reduction was found in columns K.1.9 and K.6.5, both showing a 5% decrease, while column K.1.7 exhibited no detectable deterioration. Overall, the majority of columns experienced notable degradation in structural integrity, underscoring the necessity for further comprehensive evaluations to determine the building’s continued feasibility and safety for use.

Downloads

Download data is not yet available.

References

Borrero, J. C., Synolakis, C. E., & Fritz, H. (2006). Northern Sumatra field survey after the December 2004 great Sumatra earthquake and Indian Ocean tsunami. Earthquake Spectra, 22 (S3), S93–S104. https://doi.org/10.1193/1.2206791

Riskawati, R., Yusra, A., & Mahmud, S. (2018). Analisa Perbedaan Kekuatan Beton Akibat Tsunami (Studi Kasus: Pengujian Nilai Pantul Hammer Test Pada Kolom Bangunan Mesjid Paya Peunaga Kec. Meureubo Kab. Aceh Barat). Jurnal Teknik Sipil dan Teknologi Konstruksi. https://jurnal.utu.ac.id/jtsipil/article/view/718

Samsunan, S., & Febrianti, D. (2018). Analisa Tingkat Kerusakan Struktur Kolom Terkena Tsunami. Jurnal Teknik Sipil dan Teknologi Konstruksi, 4(1), 74–84. https://doi.org/10.35308/jts-utu.v4i1.591

Sumajouw, A. J., Pandaleke, R. E., & Wallah, S. E. (2018). Perbandingan kuat tekan menggunakan hammer test pada benda uji portal beton bertulang dan menggunakan mesin uji kuat tekan pada benda uji kubus. Jurnal Sipil Statik, 6(11). E-Journal Universitas Sam Ratulangi

Tampubolon, S. P., & Antonius, D. (2024). Analisis pengaruh variasi jarak pengikat geser pada uji balok beton bertulang. Jurnal PenSil, 13(2). https://doi.org/10.21009/jpensil.v13i2.44068

Sembiring, A. Y., Wallah, S. E., & Ointu, B. M. (2019). Pengaruh pembebanan terhadap hasil pengujian hammer test pada kolom beton bertulang. Jurnal Sipil Statik, 7(2). E-Journal Universitas Sam Ratulangi

Ichsan, M., Tanjung, D., & Hasibuan, M. H. M. (2021). Analisa perbandingan hammer test dan compression testing machine terhadap uji kuat tekan beton. Buletin Utama Teknik, 17(1), 41–45. https://jurnal.uisu.ac.id/index.php/but/article/view/4312

Lin, X., Li, W., Castel, A., Kim, T., Huang, Y., & Wang, K. (2023). A comprehensive review on self-healing cementitious composites with crystalline admixtures: Design, performance and application. Construction and Building Materials, 409, 134108. https://doi.org/10.1016/j.conbuildmat.2023.134108

Li, Y., Xu, H., He, Y., Xu, Q., Fan, X., & Liu, C. (2024). Study on the correlation between indoor accelerated corrosion testing of concrete epoxy polysiloxane coating and real-sea environmental testing in the East China Sea. Case Studies in Construction Materials, 20, e02905. https://doi.org/10.1016/j.cscm.2024.e02905

Ichsan, M., Tanjung, D., Hasibuan, M.H.M., 2021. Analisa Perbandingan Hammer Test dan Compression Testing Machine Terhadap Uji Kuat Tekan Beton. Buletin Utama Teknik 17, 41–45.

Broto, A. B., Hasan, M. F. R., Sukarman, S., & Sucita, I. K. (2021). Pendampingan Pengelola Yayasan Riyadul Falah Dalam Perbaikan Bangunan Gedung Gagal Konstruksi. JMM (Jurnal Masyarakat Mandiri), 5(6), 3476–3486.

Ernawati, Tumingan, & Nugroho, B. (2022). Evaluasi Kuat Tekan Beton Menggunakan Hammer Test Dan Ultrasonic Pulse Velocity (Upv) Pada. Jurnal Ilmiah Teknik Sipil Politeknik Negeri Samarinda, 14(1), 16–22.

Fikri, M., Nurhidayah, N., Adriansyah, M. R., & Ahmadi, A. (2023). Evaluasi Kekuatan Struktur Kolom Eksisting Pada Pembangunan Mako Polres Toraja Utara Menggunakan Schimidt Hammer Test. Jurnal Ilmiah Ecosystem, 23(1), 32–39. https://doi.org/10.35965/eco.v23i1.2501

Herdiansah, Y., & Cendana, W. P. (2025). Evaluasi Kuat Tekan Beton Terpasang pada Struktur Dermaga Eksisting Berdasarkan Pengujian Destructive dan Non-Destructive ABSTRACT . Evaluation of Installed Concrete Compressive Strength on Existing Pier. 21(April), 109–127. https://doi.org/10.28932/jts.v21i1.8698

Prasetya, B., Zhafira, T., Sagara, N. J., Widorini, T., & Sitorus, M. S. (2024). Evaluasi Mutu Beton dengan Metode Non-Destructive Test pada Kolom Gedung Parkir Menara USM. Jurnal Teknik Sipil ITP, 11(1), 40–45. https://doi.org/10.21063/JTS.2024.V1101.040-45

Downloads

Published

2025-06-15

How to Cite

Mhd. Arief Diana, Michel Kasaf, Taufik, T., Anwar, K. ., & Pitri, D. T. (2025). Analisis Perbedaan Kekuatan Struktur Kolom Akibat Tsunami pada Gedung Laboratoriom Dinas PUPR Kota Banda Aceh . INSOLOGI: Jurnal Sains Dan Teknologi, 4(3), 623–630. https://doi.org/10.55123/insologi.v4i3.5510

Issue

Section

Articles