Perbedaan Nilai Laju Endap Darah (Led) dengan Metode Westergreen Manual dan Automatic Convergys Esr 10s di Puskesmas Pasar Minggu

Authors

  • Aulia Mutiara Hikmah Sekolah Tinggi Ilmu Kesehatan Kesetiakawanan Sosial Indonesia
  • Wicka Maria Tarigan Sekolah Tinggi Ilmu Kesehatan Kesetiakawanan Sosial Indonesia

DOI:

https://doi.org/10.55123/insologi.v1i5.1004

Keywords:

Erythrocyte Sedimentation Rate, Manual Westergreen, Automatic

Abstract

Examination of the erythrocyte sedimentation rate (LED) can be done by manual or automatic Westergreen methods. LED automatic machine used at the Pasar Minggu Subdistrict Health Center is the Convergys ESR 10s. This study aims to determine the difference in the measurement of the erythrocyte sedimentation rate using the Manual Westergreen for 1 hour and Automatic 30 minutes at the Pasar Minggu Subdistrict Health Center. The study used a comparative descriptive method, namely by comparing the results of the comparison of Westergreen's manual erythrocyte sedimentation rate (ED) measurement with the ICSHS standard and the Automatic method using the Convergent tool using statistical test data analysis of the Paired sample T-test. The results of the LED examination samples were analyzed by Kolmogorov-Smirnov to determine the results of the P-value of 0.20 (P-value > 0.05) the data was normally distributed so that the data could be tested using the Paired Sample T-Test. The results with the paired sample T-Test test obtained a P-value of 0.877 (P-value > 0.05). This result can be interpreted that H­0 is accepted and H1 is rejected, that there is no significant difference between Westergreen's manual erythrocyte sedimentation rate and the Automatic method.

Downloads

Download data is not yet available.

References

Aulia SN. 2017. Gambaran Nilai Laju Endap Darah (LED) Menggunakan Cara Westergren dan Cara Otomatik (Doctoral dissertation, AAK Borneo Lestari).

Bochen, K., Krasowska, A., Milaniuk, S., Kulezynska, M., Pristupa, A and Dzida. 2011. Erythrocyte sedimentation rate–an old marker with new applications. Journal of Pre-clinical and Clinical Research, 5(2)

DepKes RI. 2004. Pedoman Praktek Laboratorium Yang Benar. Jakarta.

Hidayat, T. 2014. Perbandingan Nilai Laju Endap Darah Dengan

Metode Westergren Dan Vesmatic Easy. Karya Tulis Ilmiah. Politeknik Kesehatan Bandung: Bandung.

Kratz, A., Plebani, M., Peng, M., Lee, Y.K., McCafferty, R., Machin, S.J. and International Council for Standardization in Haematology (ICSH), 2017. ICSH recommendations for modified and alternate methods measuring the erythrocyte sedimentation rate. International journal of laboratory hematology, 39(5), pp.448-457.

Krouwer, J.S., Cembrowski, G.S. and Tholen, D.W., 2014. Preliminary evaluation of quantitative clinical laboratory measurement procedures: Approved Guideline. Clinical and Laboratory Standards Institute.

Nofiyanti, I., 2017. Perbedaan hasil pemeriksaan laju endap darah metode manual dan automatic (Doctoral dissertation, Muhammadiyah University of Semarang).

Simmons, A., 1989. Hematology: a combined theoretical & technical approach. WB Saunders Company.

Sugari, N.W., Sri Arjani, I.A.M. and Ratih Kusuma Ratna Dewi, G.A., 2014. Perbedaan Hasil Laju Endap Darah Metode Westergreen Dengan Automatik Roller 20. Meditory The Journal of Medical Laboratory, 2(1), pp.28-34.

Sukarmin, M., dan Iqlima, D. 2019. Perbandingan Hasil Pengukuran Laju Endap Darah Dengan Metode Manual dan Automatic. Jurnal Manajemen Kesehatan Yayasan RS. Dr. Soetomo, 5(1), 1-5.

Seran, B.Y. 2018. Perbedaan Hasil Pemeriksaan Laju Endap Darah Metode Manual Dan Automatic Di Laboratorium RSUD Prof. Dr. W Z Johhanes Kupang [KTI]. Semarang. Analis Kesehatan Fakultas Ilmu Keperawatan Dan Kesehatan Universitas Muhammadiah Semarang

Wahyu, P.P., 2009. Sistem Peredaran Darah Pada Manusia. PT. Puri Delco: Bandung.

Wijayanti, W.A. 2018. Perbedaan Pengukuran Laju Endap Darah Menggunakan Metode Westergreen Manual Dan Automatic [KTI]. Jombang. Analis Kesehatan pada Sekolah Tinggi Ilmu Kesehatan Insan Cendekia Medika Jombang

Yana, A.D. 2019. Hitung Laju Endap Darah (LED). Ponorogo: Uwais Inspirasi Indonesia

A. A. Chamid, B. Surarso, and F. Farikhin, “Implementasi Metode AHP Dan Promethee Untuk Pemilihan Supplier,” J. Sist. Inf. Bisnis, vol. 5, no. 2, pp. 128–136, 2015, doi: 10.21456/vol5iss2pp128-136.

S. Saefudin and F. Cahyo, “Sistem Pendukung Keputusan Menentukan Pemberian Bonus Tahunan Pada Karyawan Menggunakan Metode Analytical Hierarchy Process (Ahp),” JSiI (Jurnal Sist. Informasi), vol. 6, no. 1, p. 54, 2019, doi: 10.30656/jsii.v6i1.1074.

Downloads

Published

2022-10-29

How to Cite

Hikmah, A. M., & Tarigan, W. M. (2022). Perbedaan Nilai Laju Endap Darah (Led) dengan Metode Westergreen Manual dan Automatic Convergys Esr 10s di Puskesmas Pasar Minggu . INSOLOGI: Jurnal Sains Dan Teknologi, 1(5), 669–675. https://doi.org/10.55123/insologi.v1i5.1004