Abstract

Abstract

PT. Indonesia Power Suralaya PGU has an electricity capacity of 3400 MW. Motor Primary Air Fan as the main air supplier to the boiler. To keep the Primary Air Fan motor from being disturbed, it is protected and monitored with GE Multilin 269. The research method that the author uses is the online interview and observation method regarding the motor protection system with the head of the electrical division 5-7 PT. Indonesia Power with data analysis technique that is Miles & Huberman interactive model. GE Multilin 269 output relays (eg, TRIP, AUX) used to trip the motor must change state when control power is removed from the GE Multilin 269 relay. When the input data matches the database, an output is generated. The results of the study can be concluded that the output can be an analog signal as well as an action. The action here is in the form of relay outputs, namely: (1) breaker relay, (2) assistance relay, (3) delay relay and (4) service relay. When checking the motor setpoint page 1 to check and change all alarm trips on the primary air fan motor and setpoint page 3 to check the O/L curve set so that it displays the trip time from 1 second to 8 seconds.

Downloads

Download data is not yet available.

References

Amri, R., & Darmawan, I. A. (2020). Pengujian Standar Mutu Pada Perbaikan Motor Traksi 130 Kw PT . Pindad ( Persero ) Bandung. Prosiding Seminar Nasional Pendidikan Fisika, 3(1), 415–424.

Aribowo, W., & Zaymapa, I. N. D. (2019). Sistem Proteksi Motor Berbasis Motor Manajemen Relay GE Multilin SR469 pada Motor Primary Air Fan di PLTU PAITON Unit 7. INAJEEE Indonesian Journal of Electrical and Eletronics Engineering, 2(2), 35–42. https://doi.org/10.26740/inajeee.v2n2.p1-8

Anderson Avenue.(1999). 269 Motor Management Relay Instruction Manual. Firmware Rev.: 269P. D6.0.4 Manual P/N: 1601-0013-D3 Copyright 1999 GE Multilin. Canada.

Desmira, & Aribowo, D. (2016). Desain Alat Pendeteksi Kebocoran Gas Elpiji Menggunakan Mikrokontroller Atmega16. VOLT Jurnal Ilmiah Pendidikan Teknik Elektro, 1(1), 73–80.

Fatkhurrokhman, M. (2016). Strategi Belajar Siswa Pada Kegiatan Praktik Kerja Industri Dalam Memperoleh Kompetensi. 1(1), 47–58.

Permata E, Aditama D. 2020. Sistem Kendali On/Off Circuit Breaker 150 kV AD20 Tipe 8DN2 di PT. Krakatau Daya Listrik. Energi dan Kelistrikan: Jurnal Ilmiah Vol. 12, No. 1

Permata E, Lestari I. 2021. Maintenance Preventive Pada Transformator Step-Down AV05 Dengan Kapasitas 150KV Di PT. KRAKATAU DAYA LISTRIK. Prosiding Seminar Nasional Pendidikan FKIP Universitas Sultan Ageng Tirtayasa Vol. 3, No.1.

Permata E, Zakiyya, H. P. 2021. Sistem Penyatuan Benang Dengan Berbagai Ukuran Di Dalam Mesin Muratec QPRO EX Untuk Memeriksa Kualitas Dan Membuat Benang Lebih Bagus Di PT. BUDI TEXINDO PRAKARSA (SPINNING MILL). Seminar Nasional AVoER XIII. Fakultas Teknik Universitas Sriwijaya

Sufrianti, J., & Hamzah, A. (2017). Simulasi Dan Deteksi Gangguan Belitan Stator Motor Induksi Tiga Fasa Menggunakan Arus Starting Dengan Matlab/Simulink. Jurnal Online Mahasiswa Fakultas Teknik Volume 4 No.1 Februari 2017, Volume 4(1), 1–11.

Sulastri D, Darmawan, I. A. 2022. Pengujian Elektrik Motor Induksi 3 Phase Rotor Sangkar 75 KW Di PT MESINDO TEKNINESIA. TESLA| VOL. 24 | NO. 1

Susanto, E. (2017). Pengujian Unjuk Kerja Dan Pengukuran Parameter Motor Induksi Satu Fasa. 19. http://eprints.ums.ac.id/49305/4/erwin upload 12.pdf

Y. iqbal maulana and Hendri, “Memprediksi Minat Pelanggan Membeli Produk Sepatu Menggunakan Metode Decision Tree Pada PT. Zoelindo Elite Anugerah,” Sentra Penelit. Eng. dan Edukasi, vol. 10, no. 4, p. 70, 2018.

A. Muzakir and R. A. Wulandari, “Model Data Mining sebagai Prediksi Penyakit Hipertensi Kehamilan dengan Teknik Decision Tree,” Sci. J. Informatics, vol. 3, no. 1, pp. 19–26, 2016, doi: 10.15294/sji.v3i1.4610.

Downloads

Published

2022-10-29

How to Cite

Ramandani, R., & Dwi Cahyono, B. (2022). Proteksi Motor Berbasis Relay Ge Multilin pada Primary Air Fan di PT Indonesia Power . INSOLOGI: Jurnal Sains Dan Teknologi, 1(5), 512–519. https://doi.org/10.55123/insologi.v1i5.861