Performance And Efficiency Analysis of 3.3 kWp Hybrid Solar PV Under Tropical Climate
DOI:
https://doi.org/10.55123/insologi.v5i5.9473Keywords:
Hybrid Solar PC, Household, Solar Radiation, Ambient Temperature, Performance RatioAbstract
The deployment of household-scale Rooftop Solar Photovoltaic (PV) systems has experienced rapid growth as a clean energy transition solution in tropical regions. However, the performance and power conversion efficiency of solar modules are strongly influenced by environmental parameter fluctuations, particularly solar radiation intensity and ambient temperature. This study aims to analyze the performance and operational efficiency of a 3.3 kWp household-scale Hybrid PV system based on fluctuations in solar irradiance and environmental temperature. Operational data collection was conducted over 12 hours (08:00–20:10 WIB) at 10-minute logging intervals, covering parameters of voltage, current, DC/AC power, light intensity, and temperature. Results show that the maximum solar radiation intensity reached 342.8 W/m² at 14:40 WIB with a daily average of 144.66 W/m², while the highest ambient temperature was recorded at 49.5°C at 12:50 WIB with an average of 38.74°C. The peak power output generated by the solar module (Ppv) was 432.6 W (at 08:30 WIB) with an average power of 105.18 W. Increasing ambient temperatures above Standard Test Conditions (STC) were shown to cause a reduction in module operating voltage (Vpv) and system conversion efficiency (Sitorus et al., 2025). The MPPT-based Solar Charge Controller (SCC) and energy storage battery successfully maintained the stability of household AC electrical power supply with an average served load power of 31.32 W (Wahyu Firmansyah et al., 2025). This evaluation provides technical insight into the operational characteristics and reliability of a 3.3 kWp Hybrid PV system in supporting residential electrical energy demand
Downloads
References
Astarani, T. F., Christina, S., Pardede, Y., & Matondang, A. A. (2026). Expert System for Electric Vehicle Charging Infrastructure Planning : A Scenario-Based Decision Support Framework for Two-Wheeler and Bus Fleets. 5(4), 1601–1613. https://doi.org/10.55123/insologi.v5i4.9209
Christina, S., Pardede, Y., Astarani, T. F., Hardi, S., & Anugerah, A. (2026). Sistem Pendukung Keputusan Berbasis IoT untuk Monitoring Kinerja Panel Surya dan Pemeliharaan Prediktif. 5(4), 1527–1537. https://doi.org/10.55123/insologi.v5i4.9169
DAHATE, N., & BHASME, N. R. (2019). Review on Mppt Techniques Used in Pv System. International Journal of Electrical Engineering and Technology, 10(4), 22–30. https://doi.org/10.34218/ijeet.10.4.2019.003
Hardi, S., Matondang, A. A., & Rambe, A. H. (2021). Modeling of transient caused by lightning strike at Nias high voltage substation using ATP-EMTP case study. Journal of Physics: Conference Series, 1811(1), 012049. https://doi.org/10.1088/1742-6596/1811/1/012049
Juli Sutiawan, D. E., Notosudjono, D., Rijadi, B. B., & Yamato, Y. (2024). Analisis Teknis Dan Ekonomi Pembangkit Listrik Tenaga Surya Atap Berbasis PVsyst. Journal of Electrical Engineering and Computer (JEECOM), 6(1), 110–119. https://doi.org/10.33650/jeecom.v6i1.8299
Karjadi, M. (2025). Optimalisasi Efisiensi Panel Surya dalam Sistem Pembangkit Listrik Tenaga Surya (PLTS) Skala Rumah Tangga. Ranah Research : Journal of Multidisciplinary Research and Development, 7(4), 3002–3010. https://doi.org/10.38035/rrj.v7i4.1579
Lin, C. A., Suhaiza, Z., & Nurain, M. (2025). Factors influencing households’ willingness to continue as a net energy metering (NEM) prosumer in Malaysia. Sustainable Futures, 10, 100829. https://doi.org/10.1016/j.sftr.2025.100829
Nainggolan, R., Kamil, I., Matondang, A. A., Sitorus, N., Suadi, S., Sibarani, B., & Hestukoro, S. (2026). Parametric optimization of an axial wind turbine blade for a hybrid renewable energy system integrating solar PV and micro-hydro. Science, Technology, and Communication Journal, 6(3), 385–392. https://doi.org/10.59190/stc.v6i3.395
Pijoh, F., Kusuma, B. D. P., & Purba, L. P. (2024). Pembangkit Listrik Tenaga Surya untuk Energi Ramah Lingkungan yang Berkelanjutan. Industrial & System Engineering Journals (ISEJOU), 2(2), 201–207. https://doi.org/10.37477/isejou.v2i2.631
Purba, A. M., Napitu, D. H. S., Lestari, M. W., Simangunsong, J., Hutajulu, E., Hutabarat, N. F., & Matondang, A. A. (2026). Energy Consumption and Charging Infrastructure Analysis for Electric Bus Deployment in Urban Transportation Systems. Jurnal Penelitian Pendidikan IPA, 12(4), 639–648. https://doi.org/10.29303/jppipa.v12i4.11221
Rahman, M. I., Asiah Muhamad, N., & Sulthan, S. M. (2026). Field Performance Irradiance-Dependent Characterisation Analysis of Mono-crystalline PV Modules in Brunei Darussalam. 2026 IEEE 6th International Conference in Power Engineering Applications (ICPEA), 49–52. https://doi.org/10.1109/ICPEA69349.2026.11533710
Sitorus, N., Ginting, B. B., Panjaitan, B. P., Simanjuntak, B. E., Naibaho, P. R. P., Matondang, A. A., & Simanjuntak, A. V. H. (2025). Design and Performance Evaluation of a 200 Wp Off-Grid Solar Photovoltaic Module for Renewable Energy in Indonesia. Journal of Geoscience, Engineering, Environment, and Technology, 10(3), 408–412. https://doi.org/10.25299/jgeet.2025.10.3.24981
Sitorus, N., Matondang, A. A., Elektro, J. T., Medan, P. N., Off-grid, S., & Air, P. (2026). ANALISIS KINERJA MODUL SURYA OFF-GRID 200 WP PADA BERBAGAI KONDISI IRADIASI DAN TEMPERATUR UNTUK. 7(1), 1–6.
Suparmono, S., Cholish, C., Abdullah, A., Sinambela, H., Alda, T., Aprima, A., & Simanjuntak, A. V. H. (2025). Engineering , Environment , and Technology Quantitative Assessment of Passive Load Balancing for a Designed HVAC Installation : Case study in Magnificent Hall , Deli Park. 10(3), 397–401. https://doi.org/10.25299/jgeet.2025.10.3.24696
Suprianto, Hardi, S., & Matondang, A. A. (n.d.). SISTEM PENDUKUNG KEPUTUSAN CERDAS UNTUK MENGINTEGRASIKAN PV SURYA DAN PENGISIAN. 7(1), 64–72.
Wahyu Bagus Rahmatulloh, & Aris Heri Andriawan. (2024). Rancang Bangun PLTS Menggunakan Sistem Hybrid Pada Rumah Tangga Untuk Menggurangi Ketergantungan Energi Listrik Dari PLN. Uranus : Jurnal Ilmiah Teknik Elektro, Sains Dan Informatika, 2(3), 58–72. https://doi.org/10.61132/uranus.v2i3.207
Yohana, W. Y., Nasution, T. I., Wahyuningsih, H., Matondang, A. A., & Margolang, A. R. (2024). Evaluation of Dissolved Oxygen Concentration in Different Circulation Systems on Water Quality in Fish Pond. Journal of Applied Geospatial Information, 8(1), 71–77. https://doi.org/10.30871/jagi.v8i1.7820
Z Zumhari, Hutajulu, E., Sibarani, B., Sirait, R., Anggriani, T., & Matondang, A. A. (2025). Advancing Environmental and Health Pollution Monitoring in Medan, Indonesia: A Mechatronics-Based Meta-Analysis. Journal of Geoscience, Engineering, Environment, and Technology, 10(3), 402–407. https://doi.org/10.25299/jgeet.2025.10.3.24694
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Lisa Adriana Siregar, Yussa Ananda, Ahmad Sofyan, M. Iqbal, Aprima Matondang

This work is licensed under a Creative Commons Attribution 4.0 International License.
Hak cipta pada setiap artikel adalah milik penulis.
Penulis mengakui bahwa INSOLOGI (Jurnal Sains dan Teknologi) sebagai publisher yang mempublikasikan pertama kali dengan lisensi Creative Commons Attribution 4.0 International License.
Penulis dapat memasukan tulisan secara terpisah, mengatur distribusi non-ekskulif dari naskah yang telah terbit di jurnal ini kedalam versi yang lain, seperti: dikirim ke respository institusi penulis, publikasi kedalam buku, dan lain-lain. Dengan mengakui bahwa naskah telah terbit pertama kali pada INSOLOGI (Jurnal Sains dan Teknologi).